CCT70S-CCA

Networking cable - CAT7 - S/FTP - solid 0.25 mm² - 23 AWG - EN50399 CPR Euroclass Cca-s1a,d1,a1

New

The CCT70S-Cca is a CAT7 installation networking cable compliant to the Cca standard of the Construction Product Regulation (CPR) regarding fire and flammability resistance in fixed installations, minimizing toxic smokes and providing optimal resistance to spreading fire.

In addition to its outstanding fire properties, the outer jacket of the cabling is smooth and durable for easy installation and pulling. The cable consists of 4 individually shielded twisted pair cables with solid 23 AWG conductors, overall braided shielding is provided to reduce crosstalk and system noise to a minimum resulting in higher bandwidth and improved immunity against noise and interference caused by external devices. Providing an optimized solution for 100Base-T, 1000Base-TX and 10GBase-T gigabit networks.

More information about CPR compliant cables? Click here

Inner Conductors

Shielding

Types

New

  • CCT70S-CCA/3 - 305 m plastic reel

Highlights

  • EN50399 CPR Euroclass Cca-s1a,d1,a1
  • 600 Mhz performance, up to 10GBase-T
  • IEC 60332-1 NHFR compliant
  • Al-foil individual & braided overall shielding

Cross section

  • Cross section CCT70S-CCA - Networking cable - CAT7 - S/FTP - solid 0.25 mm² - 23 AWG - EN50399 CPR Euroclass Cca-s1a,d1,a1
Physical Characteristics
EN50399 CPR Euroclass Cca-s1a,d1,a1
Type of cable S/FTP CAT7 Networking cable
Inner conductor Material BC 1 x 0.566 mm (Ø) (OFC)
Section 0.25 mm²
American Wire Gauge 23 AWG
Number of conductors 8 (4 pairs)
Insulation Colours Green / White & Green ; Blue / White & Blue ; Orange / White & Orange ; Brown / White & Brown
Shielding Aluminium foil Al-mylar, 100% coverage - 25% Overlap
Separator None
Overall shielding Braiding TC 10 x 8 x 0.08 mm (Ø) (OFC)
Outer jacket Colours Black
Material LSZH
Electrical Characteristics
Max. Delay / Skew <25 (ns / 100 m)
Rated voltage 300 V
Nom. Velocity of propagation 76 %
Characteristic impedance 100 Ω ± 15 Ω
Max. conductor DC resistance 7.9 Ω / 100 m
DC resistance unbalanced < 2 %
Nom. mutual capacitance ≤ 5.6 (nF / 100 m)
Pair to ground capacitance unbalance ≤ 330 (pF / 100 m)

Meter indicator

Convenient indication on every meter of cable.

Find out more about Meter indicator

LSHF

An extra layer of protection in case of fire.

Find out more about LSHF

CAT7

Get the maximum performance out of your ethernet cable.

Find out more about CAT7

CCA

Compliant with Euroclass Cca of the Construction Products Regulation.

Find out more about CCA
Like being first?
Be first in line to receive PROCAB special offers, new product launches and news about exhibitions

    * fields are required

      Our latest news

      Top