CCT65F-B2CA

DiscontinuedNetworking cable - CAT6A - U/FTP - solid 0.25 mm² - 23 AWG - EN50399 CPR Euroclass B2ca-s1a,d1,a1
There is no successor for this product
AV & IT
Contractor Series
  • EN50399 CPR Euroclass B2ca-s1a,d1,a1
  • 500 Mhz performance, up to 10GBase-T
  • Al-foil shielding
CAT6 500 MHz
LSHF
Meter Indicator
B2CA
Where to buy?

Description

The CCT65F-B2ca is a CAT6A installation networking cable compliant to the B2ca standard of the Construction Product Regulation (CPR) regarding fire and flammability resistance in fixed installations, minimizing toxic smokes and providing optimal resistance to spreading fire.

In addition to its outstanding fire properties, the outer jacket of the cabling is smooth and durable for easy installation and pulling. The cable consists of 4 individually shielded twisted pair cables with solid 23 AWG conductors. This way, crosstalk and system noise is reduced to a minimum, resulting in aigher bandwidth and improved immunity against noise and interference caused by external devices. Providing an optimized solution for 100Base-T, 1000Base-TX and 10GBase-T gigabit networks.

More information about CPR compliant cables? Click here

Product variants

Discontinued

CCT65F-B2CA/3 305 m plastic reel There is no successor for this product

Specifications

Product features

Application AV & IT
Series Contractor Series

Physical characteristics

Type of cable U/FTP CAT6A Networking cable
EN50399 CPR Euroclass B2ca-s1a,d1,a1
Inner conductor Material BC 1 x 0.56 mm (Ø) (OFC)
Section 0.00039 “²
American Wire Gauge 23 AWG
Insulation Colours Green / White & Green ; Blue / White & Blue ; Orange / White & Orange ; Brown / White & Brown
Material Foamed PE 1.3 mm Ø
Number of conductors 8 (4 pairs)
Conductor twisting Yes
Shielding Aluminium foil Aluminium foil 100% coverage - 25% Overlap
Outer jacket Material LSHF 7.3 mm (Ø)
Colours Black

Standards and regulations

RoHS2 compliant According EU Directive 2011/65/EU
Reach compliant According EC 1907/2006
CPR Euroclass B2ca-s1a,d1,a1
Flammability test According EN 60332-1-2
Indoor / outdoor UV resistant (UL1581, UVA, 720 h)
Smoke emissions According IEC 61034
Zero halogen compounds According EN 50267-2-1
IEC 60754

Mechanical characteristics

Temperature range Fixed installation - 41 °F till + 176 °F
Mobile installation - 59 °F till + 176 °F
UV resistant Yes

Electrical characteristics

Max. conductor DC resistance 8.3 Ω / 100 m
DC resistance unbalanced < 2 %
Max. Delay / Skew <25 (ns / 3937.0079 ")
Rated voltage 300 V
Nom. Velocity of propagation 74 %
Characteristic impedance 100 Ω ± 15 Ω
Nom. mutual capacitance ≤ 5.6 (nF / 100 m)
Pair to ground capacitance unbalance ≤ 330 (pF / 100 m)

Cross section

Technology

Cable properties

100 Ohm

The 100Ω cables are ideal for the transmission of digital signals. This impedance is mostly used in our wide range of UTP cables.

Solid copper

The signal cables consist of a solid inner conductor. Typically, you will find solid core wires in situations where the wire is not designed to be continuously flexed and where the wire may be exposed to corrosive elements or adverse weather condition. A solid copper core can achieve an even more compact diameter than a stranded wire with the same current carrying capability.

Aluminum Foil

Aluminum foil shielding is ideal for reflecting electromagnetic interference (EMI) and is often used in combination with a braided wire to absorb EMI.

Meter indicator

For ease of installation these bulk cables are provided with an indication on every meter of the cable. This enables installers to have a clear and efficient indication of how many meters they still have available on their reel.

LSHF

LSHF stands for Low Smoke, Halogen Free. This term refers to Halogen free flame retardant thermoplastic material used as a sheathing compound in cables. In the event of a fire or when exposed to high levels of heat, the chemicals in the jacket removes heat from the flame, whilst the reaction produces water as a by-product to help quench the flame.  As a result, the cable will emit very low levels of smoke, and non-toxic levels of poisonous halogen gasses.

CAT6A

CAT6A can handle a 10 gigabit network (10000Mbps at 500Mhz). This cable can bridge distances up to 100 meters.

B2CA

Class B2ca is the highest CPR class used in fixed installations, providing the greatest resistance to spreading fire while maintaining the lowest emission of toxic smoke.

Downloads

Information sheet English

Create a document that summarizes all the details of this product. The product information sheet can contain: product descriptions, technical drawings, technical specifications, ...

Declarations of conformity

Get in touch

We are glad you are interested in our solutions. For a personalised quote for this product, please contact our sales department or make an appointment with one of our global sales representatives.

Request a quote
Top