CLS215-B2CA

Loudspeaker cable - 2 x 1.5 mm² - 16 AWG - EN50399 CPR Euroclass B2ca-s1b,d0,a1
AV & IT
Contractor Series
  • EN50399 CPR Euroclass B2ca-s1b,d0,a1
  • 16 AWG (1.5 mm²) thin and dense stranded conductors
  • Class 5 IEC 60228 compliant
LSHF
Meter Indicator
Made in Europe
B2CA
Where to buy?

Description

The CLS215-B2ca series are 2-core installation loudspeaker cables compliant to the B2ca standards of the Construction Product Regulation (CPR) regarding fire and flammability resistance in fixed installations, minimizing toxic smokes and providing optimal resistance to spreading fire. In addition to its outstanding fire properties, the outer jacket of the cabling is smooth and durable for easy installation and pulling.

The CLS2xx series consists of three models with individually polyolefin isolated conductors in sections ranging from 1.5 mm² (16 AWG) up to 4 mm² (11 AWG) which are composed of stranded bare copper wires. The stranding keeps the cable flexible and easy to handle. The cable can be used in both indoor and outdoor or in humid environments.

More information about CPR compliant cables? Click here

Product variants

Available now

CLS215-B2CA/1 100 m wooden reel
CLS215-B2CA/3 300 m wooden reel

Specifications

Product features

Application AV & IT
Series Contractor Series

Physical characteristics

Type of cable 2-core loudspeaker cable
EN50399 CPR Euroclass B2ca-s1b,d0,a1
Inner conductor Material BC 28 x 0.25 mm (Ø) (OFC)
Section 0.0023 “²
Number of conductors 2
Insulation Material Polyolefin 3.1 mm (Ø)
Filling None
Separator None
Inner conductor American Wire Gauge 16 AWG
Insulation Colours Red / Blue
Conductor twisting Yes
Outer jacket Material Polyolefin 9 mm (Ø)
Colours Black

Standards and regulations

RoHS2 compliant According EU Directive 2011/65/EU
Reach compliant According EC 1907/2006
Indoor / outdoor UV resistant (UL1581, UVA, 720 h)
Smoke emissions According IEC 61034
Zero halogen compounds According EN 50267-2-1
IEC 60754
CPR Euroclass B2ca-s1b,d0,a1
Flammability test According EN 60332-1-2

Mechanical characteristics

Temperature range Mobile installation - 41 °F till + 176 °F
Fixed installation - 59 °F till + 176 °F
UV resistant Yes

Electrical characteristics

Max. conductor DC resistance 13.3 (Ω / Km)
Dielectric strength 2 (KV / 1 min. DC)
Rated voltage 500 V

Cross section

Technology

Cable properties

Meter indicator

For ease of installation these bulk cables are provided with an indication on every meter of the cable. This enables installers to have a clear and efficient indication of how many meters they still have available on their reel.

LSHF

LSHF stands for Low Smoke, Halogen Free. This term refers to Halogen free flame retardant thermoplastic material used as a sheathing compound in cables. In the event of a fire or when exposed to high levels of heat, the chemicals in the jacket removes heat from the flame, whilst the reaction produces water as a by-product to help quench the flame.  As a result, the cable will emit very low levels of smoke, and non-toxic levels of poisonous halogen gasses.

B2CA

Class B2ca is the highest CPR class used in fixed installations, providing the greatest resistance to spreading fire while maintaining the lowest emission of toxic smoke.

Downloads

Information sheet English

Create a document that summarizes all the details of this product. The product information sheet can contain: product descriptions, technical drawings, technical specifications, ...

Declarations of conformity

Get in touch

We are glad you are interested in our solutions. For a personalised quote for this product, please contact our sales department or make an appointment with one of our global sales representatives.

Request a quote
Top