CCT50F

DiscontinuedNetworking cable - CAT5E - F/UTP - solid 0.20 mm² - 24 AWG - FlamoFlex™
There is no successor for this product
AV & IT
Contractor Series
  • Flamoflex™ IEC 60332-1 installation jacket
  • Al-foil overall shielding
  • 100 Mhz performance, up to 1000Base-T
Shielded
CAT5E 100 MHz
HD Base T Compliant
IEC-60332
LSHF
Meter Indicator
Where to buy?

Description

The CCT50F is a CAT5E installation networking cable featuring a Flamoflex™ outer jacket compliant to the IEC 60332-1 standard regarding fire and flammability resistance in public installations. The Flamoflex™ material is specifically designed with installers convenience in mind, offering a smooth and durable outer jacket for easy installation and pulling. The conductor section consists of 4 pair solid 24 AWG conductors guaranteeing an optimal signal transmission, while the overall aluminum foil shielding with drain wire offers improved immunity against noise and interference caused by external devices. CCT50F Supports 10Base-T, 100Base-TX and 1000Base-T gigabit.

Product variants

Discontinued

CCT50F/3 305m reel in a box Replaced by

Specifications

Product features

Application AV & IT
Series Contractor Series

Physical characteristics

Inner conductor Insulation Material HDPE 0.040 " (Ø)
Colours Green / White & Green ; Blue / White & Blue ; Orange / White & Orange ; Brown / White & Brown
Shielding Aluminium foil Al-mylar, 100% coverage - 25% Overlap
Drain wire TC 1 x 0.4 mm (Ø) (OFC)
Outer jacket Material NHFR 6.0 mm (Ø)
Colours Black
Type of cable F/UTP CAT5E Networking cable
Inner conductor Material BC 1 x 0.5 mm (Ø) (OFC)
Section 0.00031 “²
Separator None
Inner conductor American Wire Gauge 24 AWG
Number of conductors 8 (4 pairs)
Conductor twisting Lay length ≤ 30 mm

Standards and regulations

RoHS2 compliant According EU Directive 2011/65/EU
Reach compliant According EC 1907/2006
Flammability test According IEC 60332-1
Indoor / outdoor Indoor
Circuit integrity n/a
Smoke emissions According IEC 61034
Zero halogen compounds According EN 50267-2-1
IEC 60754
Cabling standard ANSI TIA-EIA 568B

Mechanical characteristics

Temperature range Fixed installation - 68 °F till + 167 °F
Mobile installation - 59 °F till + 140 °F
Bending radius Fixed installation 4 x outer diameter
Mobile installation 6 x outer diameter

Electrical characteristics

Dielectric strength 1.5 (KV / 1 min. DC)
Max. Delay / Skew 45 (ns / 3937.0079 ")
Rated voltage 300 V
Characteristic impedance 100 Ω ± 15 Ω
Nom. mutual capacitance ≤ 5.6 (nF / 100 m)

Cross section

Technology

Cable properties

IEC60332

The outer jacket of all PROCAB cables complying to IEC60332 will extinguish itself when that cable is briefly exposed to a small flame.  

LSHF

LSHF stands for Low Smoke, Halogen Free. This term refers to Halogen free flame retardant thermoplastic material used as a sheathing compound in cables. In the event of a fire or when exposed to high levels of heat, the chemicals in the jacket removes heat from the flame, whilst the reaction produces water as a by-product to help quench the flame.  As a result, the cable will emit very low levels of smoke, and non-toxic levels of poisonous halogen gasses.

Meter indicator

For ease of installation these bulk cables are provided with an indication on every meter of the cable. This enables installers to have a clear and efficient indication of how many meters they still have available on their reel.

CAT5E

CAT5E can handle a gigabit Ethernet network (1000Mbps at 100Mhz) and is designed to reduce crosstalk better that CAT5.

100 Ohm

The 100Ω cables are ideal for the transmission of digital signals. This impedance is mostly used in our wide range of UTP cables.

Solid copper

The signal cables consist of a solid inner conductor. Typically, you will find solid core wires in situations where the wire is not designed to be continuously flexed and where the wire may be exposed to corrosive elements or adverse weather condition. A solid copper core can achieve an even more compact diameter than a stranded wire with the same current carrying capability.

Flamoflex™

Cables that are featured with a Flamoflex™ outer jacket are compliant to the IEC 60332-1 standard regarding fire and flammability resistance in public installations. The Flamoflex™ material is specifically designed with installers convenience in mind, offering a smooth and durable outer jacket for easy installation and pulling capabilities to guide the cable around a corner.

Aluminum Foil

Aluminum foil shielding is ideal for reflecting electromagnetic interference (EMI) and is often used in combination with a braided wire to absorb EMI.

Downloads

Information sheet English

Create a document that summarizes all the details of this product. The product information sheet can contain: product descriptions, technical drawings, technical specifications, ...

  • download Product information sheet - EN

Get in touch

We are glad you are interested in our solutions. For a personalised quote for this product, please contact our sales department or make an appointment with one of our global sales representatives.

Request a quote
Top